MicroController Pros Home Page My Account  Cart Contents  Checkout  
  Store » EM1000-TEV My Account  |  Cart Contents  |  Checkout   
Quick Find
 
Enter keywords to find the product you are looking for in the Quick Find field above

or use
Advanced Search
Categories
Accessory Boards->
8051->
ADI Blackfin
ARM->
Atmel AVR->
Cypress PSoC
Freescale->
FTDI->
Fujitsu
Locktronics
Maxim
Microchip PIC->
MIPS
National Semiconductor
Parallax
Renesas->
Silicon Labs
ST Microelectronics->
Texas Instruments->
Tibbo->
Zilog
Books->
Displays->
E-Blocks
EEPROM/EPROM/FLASH
Embedded Ethernet->
Embedded Software->
I/O Modules->
Parts & Components->
Pick & Place Tools
Programmable Logic (PLD)
Prototype PCBs->
Robotics
ROM/Flash Emulators
Test & Measurement->
Tutorial CD-ROMs
Universal Programmers->
Wireless->
Information
Intro to Embedded Tools
Embedded News Digest
Useful Resources
Shipping & Returns
Warranty & Liability
Privacy Notice
Conditions of Use
Contact Us
EM1000-TEV

Back to 4x Serial to Ethernet Terminal Evaluation Kit Ordering Page

The TEV-LB1 board carries a 128x96, 4-bit RITDISPLAY RGS13128096 OLED panel. This panel is based on a SOLOMON SSD1329 controller.

Related datasheets, as well as the schematic diagram for the TEV-LB1 board can be found on Tibbo website.

Interconnection between the EM1000 and the panel

Pin #(1) EM1000 I/O line Panel
5GPIO48 ---
6 GPIO47 ---
7 GPIO46 ---
8 GPIO39/P4.7 D7
9 GPIO38/P4.6 D6
10 GPIO37/P4.5 D5
11 GPIO36/P4.4 D4
12 GPIO35/P4.3D3
13 GPIO34/P4.2 D2
14 GPIO33/P4.1 D1
15 GPIO32/P4.0 D0
16 GPIO44RST
17 GPIO43D/C
18 GPIO42R/W
19GPIO41 E
20 GPIO40CS

Pin number 1 on the TEV-LB1 connector.

Required initialization code in Tibbo BASIC application

For correct panel operation, click Project, Settings, and select EM1000 or EM1000W platform. Additionally, click Customize to open a Customize Platform dialog. In the dialog, double-click the Display Panel Type line and choose Solomon SSD1329 (Ritdisplay RGS13128096).

The following initialization code should also be added to your project:



lcd.iomapping = 44,43,42,41,40,4 RST,DC,WR,RD,CS,data_bus
(W is marked R/W on the schematic diagram, RD is marked E)
io.num=PL_IO_NUM_40
io.enabled=YES
io.num=PL_IO_NUM_41
io.enabled=YES
io.num=PL_IO_NUM_42
io.enabled=YES
io.num=PL_IO_NUM_43
io.enabled=YES
io.num=PL_IO_NUM_44
io.enabled=YES
lcd.width=128
lcd.height=96
lcd.rotated=NO
lcd.inverted=NO
lcd.enabled=YES

Back to 4x Serial to Ethernet Terminal Evaluation Kit Ordering Page